Pascal and Francis Bibliographic Databases

Help

Search results

Your search

kw.\*:("VITALLIUM")

Document Type [dt]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Author Country

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 25 of 33

  • Page / 2
Export

Selection :

  • and

THE ROLE OF THE SURFACE TENSION AND THE CONTACT ANGLES OF PERILYMPH IN STAPES SURGERY = LE ROLE DE LA TENSION SUPERFICIELLE ET DES ANGLES DE CONTACT DE LA PERILYMPHE DANS LA CHIRURGIE DE L'ETRIERVAN CAMP KJ; CRETEN WL; MARQUET J et al.1973; ACTA OTO-LARYNGOL.; SUEDE; DA. 1973; VOL. 75; NO 1; PP. 61-63; ABS. FR. ALLEM.; BIBL. 7REF.Serial Issue

ESTUDIO DE MATERIALES METALICOS RECUBIERTOS DE CEROMICA PARA APLICACION EN EL COMPO DE LAS ENDOPROTESIS. = ETUDE DE MATERIAUX METALLIQUES RECOUVERTS DE CERAMIQUE POUR APPLICATION DANS LE DOMAINE DES ENDOPROTHESESRUIZ FERNANDEZ J; DE LA ROSA T; ALONSO LLAMES M et al.1976; REV. METALURG.; ESP.; DA. 1976; VOL. 12; NO 4; PP. 196-203; ABS. ANGL.; BIBL. 13 REF.Article

DAS FESTIGKEITS- UND ELASTISCHE VERHALTEN VON METALLEN = LA RESISTANCE ET LE COMPORTEMENT ELASTIQUE DES METAUXSCHWICKERATH H.1978; DTSCHE ZAHNAERZTL. Z.; DEU; DA. 1978; VOL. 33; NO 9; PP. 643-649; ABS. ENG; BIBL. 7 REF.Article

ORGANIC SURFACE FILM CONTAMINATION OF VITALLIUM IMPLANTSCARTER JM; FLYNN HE; MEENAGHAN MA et al.1981; J. BIOMED. MATER. RES.; ISSN 0021-9304; USA; DA. 1981; VOL. 15; NO 6; PP. 843-851; BIBL. 11 REF.Article

CORROSION OF BASE METAL ALLOYS IN VITRO.ESPEVIK S.1978; ACTA ODONTOL. SCAND.; SUEDE; DA. 1978; VOL. 36; NO 3; PP. 113-116; BIBL. 2 REF.Article

SURFACE INVESTIGATIONS OF OXIDE LAYERSON COBALT-CHROMIUM-ALLOYED ORTHOPEDIC IMPLANTS USING ESCA TECHNIQUE.OHNSORGE J; HOLM R.1978; MED. PROGR. TECHNOL.; GERM.; DA. 1978; VOL. 5; NO 4; PP. 171-177; BIBL. 14 REF.Article

UNTERSUCHUNGEN DES KONTAKTGEWEBES VON BLOUNTSCHEN VITALLIUMKLAMMEN MIT HILFE DER INSTRUMENTELLEN NEUTRONENAKTIVIERUNGSANALYSE = ETUDES DU TISSU EN CONTACT AVEC L'AGRAFE EN VITALLIUM DE BLOUNT A L'AIDE DE L'ANALYSE D'ACTIVATION NEUTRONIQUE INSTRUMENTALESCHNIEWIND EO; KASPEREK K; OHNSORGE J et al.1975; Z. ORTHOP. GRENZGEB.; DTSCH.; DA. 1975; VOL. 113; NO 2; PP. 209-216; ABS. ANGL.; BIBL. 18 REF.Article

POROUS VITALLIUM IN IMPLANT SURGERYCAMERON HU; PILLIAR RM; MACNAB I et al.1974; J. BIOMED. MATER. RES.; U.S.A.; DA. 1974; VOL. 8; NO 5; PP. 283-289; BIBL. 6 REF.Article

ZUR WIEDERVERWENDBARKEIT DENTALER KOBALT-CHROM-LEGIERUNGEN = UTILISATION REPETEE DES ALLIAGES DENTAIRES AU CHROME-COBALTMARX H.1974; DTSCHE ZAHNAERZTL. Z.; DTSCH.; DA. 1974; VOL. 29; NO 11; PP. 1008-1013; ABS. ANGL. FR.; BIBL. 11REF.Article

AN UNUSUAL REACTION IN MUSCLE IN ASSOCIATION WITH A VITALLIUM PLATE: A REPORT OF POSSIBLE METAL HYPERSENSITIVITY. = UNE REACTION INHABITUELLE DU MUSCLE ASSOCIEE A UNE PLAQUE DE VITALLIUM. RELATION D'UNE HYPERSENSIBILITE POSSIBLEHALPIN DS.1975; J. BONE JOINT SURG., BRIT. ED.; G.B.; DA. 1975; VOL. 57; NO 4; PP. 451-453; BIBL. 6 REF.Article

IMMUNOBLASTIC LYMPHOMA AT THE SITE OF AN INFECTED VITALLIUM BONE PLATEDODION P; PUTZ P; AMIRI LAMRASKI MH et al.1982; HISTOPATHOLOGY; ISSN 0309-0167; GBR; DA. 1982; VOL. 6; NO 6; PP. 807-813; BIBL. 15 REF.Article

IMPLANT OF ARTICULAR EMINENCE FOR RECURRENT DISLOCATION OF THE TEMPOROMANDIBULAR JOINT.HOWE AG; KENT JN; FARRELL CD et al.1978; J. ORAL SURG.; USA; DA. 1978; VOL. 36; NO 7; PP. 523-526; BIBL. 28 REF.Article

ADHERENCE OF CERAMIC COATINGS ON CHROMIUM-COBALT STRUCTURESDUNN B; REISBICK MH.1976; J. DENT. RES.; U.S.A.; DA. 1976; VOL. 55; NO 3; PP. 328-332; BIBL. 11 REF.Article

DER ALLOPLASTISCHE GELENKFLAECHENERSATZ AM HUEFTGELENK. VORLAEUFIGE MITTEILUNG = LE REMPLACEMENT ALLOPLASTIQUE DE LA SURFACE ARTICULAIRE DE LA HANCHE. COMMUNICATION PRELIMINAIREWAGNER H.1975; ARCH. ORTHOP. UNFALL.-CHIR.; DTSCH.; DA. 1975; VOL. 82; NO 2; PP. 101-106; ABS. ANGL.; BIBL. 5REF.Article

IMPROVED PROCESSING OF CO-CR-MO-C SURGICAL IMPLANT ALLOYSHOLLANDER R; WULFF J.1974; METALS ENGNG QUART.; U.S.A.; DA. 1974; VOL. 14; NO 4; PP. 37-38; BIBL. 7 REF.Article

A NEW FIXATION DEVICE FOR SUPRACONDYLAR AND LOW FEMORAL SHAFT FRACTURES = UN NOUVEAU DISPOSITIF DE FIXATION POUR LES FRACTURES SUPRACONDYLIENNES ET DIAPHYSAIRES BASSES DU FEMURSHELTON ML; GRANTHAM SA; NEER CS II et al.1974; J. TRAUMA; U.S.A.; DA. 1974; VOL. 14; NO 10; PP. 821-835; BIBL. 4 REF.Article

CORROSION-ACCELERATED MECHANICAL FAILURE OF A VITALLIUM NAIL-PLATE = DEFAILLANCE MECANIQUE ACCELEREE PAR LA CORROSION D'UN CLOU PLAQUE EN VITALLIUMROSE RM; SCHILLER AL; RADIN EL et al.1972; J. BONE JOINT SURG., AMER. ED.; U.S.A.; DA. 1972; VOL. 54; NO 4; PP. 854-862; BIBL. 11 REF.Serial Issue

RESTORATION OF BLOOD FLOW TO ISCHAEMIC KNEE JOINTS BY VITALLIUM IMPLANTS = RESTAURATION DE LA VASCULARISATION DE GENOUX ISCHEMIQUES PAR DES IMPLANTS DE VITALLIUMBROOKES M.1972; GUY'S HOSP. REP.; G.B.; DA. 1972; VOL. 121; NO 1; PP. 31-35; BIBL. 3REF.Serial Issue

TOTAL KNEE REPLACEMENT IN RHEUMATOID ARTHRITIS = PROTHESE TOTALE DU GENOU DANS LA POLYARTHRITE RHUMATOIDE1972; RHEUMATOL. PHYS. MED.; G.B.; DA. 1972; VOL. 11; NO 8; PP. 391-399; H.T. 1; BIBL. 10 REF.Serial Issue

Effect of silicon ion implantation on the properties of a cast Co-Cr-Mo alloyKAMINSKI, M; BASZKIEWICZ, J; KOZUBOWSKI, J et al.Journal of materials science. 1997, Vol 32, Num 14, pp 3727-3732, issn 0022-2461Article

NEUTRON ACTIVATION STUDIES OF THE IN-BODY CORROSION OF HIP-JOINT PROSTHESES MADE OF CO-CR-ALLOYS = ANALYSE PAR ACTIVATION NEUTRONIQUE DE LA CORROSION DANS LE CORPS DES PROTHESES D'ARTICULATION DE HANCHE FAITES EN ALLIAGES CO-CRHOFMANN J; WIEHL N; MICHEL R et al.1982; JOURNAL OF RADIOANALYTICAL CHEMISTRY; ISSN 0022-4081; CHE; DA. 1982; VOL. 70; NO 1-2; PART. 2; PP. 85-107; BIBL. 37 REF.Conference Paper

SOME CURRENT USES FOR METALS IN, ON, AND AROUND YOUR BODY = METALLE FUER DIE IMPLANTMEDIZIN = METAUX POUR IMPLANTS MEDICAUXMCINTYRE RD.1982; MATER. ENG.; USA; DA. 1982-09; VOL. 96; NO 3; PP. 40-47Article

ESCA-UNTERSUCHUNGEN ZUR BILDUNG UND WIEDERHERSTELLUNG DER PASSIVSCHICHT AUF VITALLIUM = ETUDES PAR ANALYSE CHIMIQUE PAR SPECTROSCOPIE ELECTRONIQUE DE LA FORMATION ET DE LA RESTAURATION DE LA COUCHE PASSIVE SUR LE VITALLIUMHOLM R; OHNSORGE J.1981; Z. ORTHOP. IHRE GRENZGEB.; ISSN 0044-3220; DEU; DA. 1981; VOL. 119; NO 5; PP. 439-444; ABS. ENG; BIBL. 9 REF.Article

Effects of alloy additions on the fatigue properties of cast Co-Cr-Mo alloy used for surgical implantsZHUANG, L. Z; LANGER, E. W.Journal of materials science. 1990, Vol 25, Num 1B, pp 683-689, issn 0022-2461, 7 p.Article

BIOMECHANIK - PROBLEMSTELLUNGEN IM BEREICH DES MENSCHLICHEN SKELETTS. T. 1 = BIOMECHANICS - PROBLEMS IN THE FIELD OF HUMAN SKELETON. PT. 1NASEBAND K; ZIEBS J.1981; AMTS MITTEILUNGSBL. BUNDESANST. MATERIALPRUEF.; DEU; DA. 1981-09; VOL. 11; NO 3; PP. 217-222; BIBL. 10 REF.Article

  • Page / 2